Contractor Disputes
Bordin Contractor Dispute
Client: Ingrid Bordin
Address: 310 Forestgate Ct. Sandy Springs, GA 30350
Inspection Date: 5-15-2026
These are the results of the inspection for “homeowner concerns” about the siding repairs and replacement at the townhouse located at the address above. This is not a warranty but is a visual inspection and survey of the materials and components that were repaired, replaced and installed based on National Professional Guidelines. These are the results of the inspection. Please see the photos in the report.
The property may be acceptable if the items listed in the report are considered. It is advised to have a certified installer or contractor check for service or repair if needed. There may be other hidden conditions but none were discovered at this inspection. If you have any questions about your report or repairs, please let me know.
ITEMS
SIDING AT ROOF SHINGLES
Cannot see roof-to-wall flashing (coming to daylight) at the townhouse wall siding on the right, connected to this townhouse when viewing from the rear yard
WATER INTRUSION
The owner stated and has photos showing there has been water intrusion after work was completed and water pouring between fire walls at her storage room.
SIDING REPLACEMENT
The owner showed photos she took during the siding repair and replacement that recorded the work in progress.
PERMIT REQUIREMENT
General repair work to single family, duplex, multi-family, or non-residential structures do not need a permit if total work is less than $10,000.00.
Contractor-Homeowner Dispute Burch
Client: Kevin and Nancy Burch
Address: 3540 Lochmill Dr. Loganville, GA. 30052
Date: 4/15/2026
Building Face: South
Conditions: Sunny
Temperature: 86
Age: Construction 3 yrs.
These are the general results for a basic site visit to conform “Defective Building and Incomplete Construction for the home, property or structure located at the address above. This is not a warranty but it is a visual inspection and survey of the systems and components of this property based on National Professional Guidelines.
This page is a summary of various conditions found. Items or components found defective, need repair or lack maintenance may be identified here, in the report and or in the photo file. The information summarized here is my best opinion following the inspection
ITEMS
GROUNDS
The soil erosion control materials are deteriorated and silt screens are missing. The original screen installation was not doubled and is now incomplete. In Georgia erosion control devices must go all the way around the perimeter of the lot and terminates only at the gravel driveway where there must remain proper ground cover. There are construction debris in the soil and can see soil erosion and soil loss at the front and sides of the house
BUILDIING GENERAL
The structure is considered a partial shell only. The building lumber has been exposed to UV rays, water penetration at several areas. Some building materials are damaged, some needs to be replaced, some worn and some weathered.
FRAMING
There is defective wall framing, missing wall framing components, improper location of walls based on owners plans and agreements. The owner identified door frame openings are not the right size for doors at areas and or improperly located as agreed to be installed
ROOF FRAMING
There is defective roof framing, improper roof rafter spans, missing roof braces at several areas. Roof rafters over the attic of the right side of the house are undersized for the load and span.
CONCRETE FLOOR AND FOUNDATION
The original foundation and floor slab were smaller than the new house floor area. It is advised to verify are the footings and foundations properly located where the newly located weight bearing walls are currently located.
Tarantino Predrywall Report
Client: Arthur Tarantino
Address: 190 Guthrie Rd. Whitesburg, GA. 30185
Date: 11-25-2024
These are the results of the inspection for the Framing and Pre-Drywall inspection at the
home, property or building located at the address above. This is not a warranty but it is
a visual inspection and survey of the systems and components of this property based
on National Professional Guidelines.
This document is a summary of various conditions found at the reinspection.